Top of the page

d&b audiotechnik R70 Ethernet to CAN interface (NO LONGER AVAILABLE)

Item No. Z6124.000
Ethernet to CAN Interface The R70 Ethernet to CAN interface provides two RJ 45 CAN connectors with a built-in switchable terminator as well as a LAN connector. The R70 contains a web interface for configuration using a standard web browser. Up to five R70 interfaces in TCP/IP mode may be connected t
Login for Dealer Pricing
Click below for direct download from our manufacturers.

Description

Ethernet to CAN Interface

The R70 Ethernet to CAN interface provides two RJ 45 CAN connectors with a built-in switchable terminator as well as a LAN connector. The R70 contains a web interface for configuration using a standard web browser. Up to five R70 interfaces in TCP/IP mode may be connected to a PC and simultaneously operated by the R1 software.

The R70 is designed to connect the d&b Remote network (CAN-Bus) to a PC via Ethernet (TCP/IP or UDP/IP).

The R70 must only be used within a d&b sound reinforcement system.

The device can be used within applications according to the standard EN 60849 (IEC 60849) ‘Sound Systems for Emergency Purposes’ (voice evacuation systems).
The device is not intended for direct connection to telecommunication networks.

Power supply
  • Supply voltage: 10 V to 30 V DC / 330 mA, or PoE (Power over Ethernet)
  • DC IN (barrel connector): to accept coaxial plug 2.1 x5.5 x 9.5 mm, Centre Positive Standard
Operating conditions
  • Temperature range: – 40° C to + 50° C (– 40° F – + 122° F)
Controls and indicators
  • Termination: built-in switchable terminator
  • Termination of CAN-Bus with internal resistor: 120  / 1/4 W / ± 5%, with corresponding status LED
  • Indicators (Status LEDs): ON, CAN, ERROR, LAN, TERMINATE
Connectors
  • LAN (Ethernet): 1 x RJ 45 connector
  • CAN: 2 x RJ 45 connectors, wired in parallel
Hardware
  • Controller: 16 Bit
  • Program Flash: 256 kB
  • Data Flash: 8 MB
  • SRAM Size: 256 kB
  • EEPROM Size: 8 kB
  • Additional features: CAN galvanically isolated
  • CAN Specification: 2.0 A/B
  • CAN-Bus coupling: High Speed, according to ISO 11898, galvanically isolated
  • Max. CAN Baud Rate: 1 Mbit/s
Ethernet Specification
  • Ethernet: 10/100 M Base-F, IEEE 802.3u
  • Power over Ethernet (PoE): IEEE 802.3af
Housing/Dimensions/Weight
  • Housing: Extruded aluminium
  • Dimensions (height x width x depth): 115x110x35 mm [4.5″ x 4.3″ x 1.4″]
  • Weight: 230 g (0.5 lb)

Product Details

RRP
$ 3025.00
Brand
d&b audiotechnik
Product Group
Electonics
Product Category
Networking
Item No. Z6124.000

d&b audiotechnik R70 Ethernet to CAN interface (NO LONGER AVAILABLE)

Ethernet to CAN Interface The R70 Ethernet to CAN interface provides two RJ 45 CAN connectors with a built-in switchable terminator as well as a LAN connector. The R70 contains a web interface for configuration using a standard web browser. Up to five R70 interfaces in TCP/IP mode may be connected t
Login for Dealer Pricing
Click below for direct download from our manufacturers.

Description

Ethernet to CAN Interface

The R70 Ethernet to CAN interface provides two RJ 45 CAN connectors with a built-in switchable terminator as well as a LAN connector. The R70 contains a web interface for configuration using a standard web browser. Up to five R70 interfaces in TCP/IP mode may be connected to a PC and simultaneously operated by the R1 software.

The R70 is designed to connect the d&b Remote network (CAN-Bus) to a PC via Ethernet (TCP/IP or UDP/IP).

The R70 must only be used within a d&b sound reinforcement system.

The device can be used within applications according to the standard EN 60849 (IEC 60849) ‘Sound Systems for Emergency Purposes’ (voice evacuation systems).
The device is not intended for direct connection to telecommunication networks.

Power supply
  • Supply voltage: 10 V to 30 V DC / 330 mA, or PoE (Power over Ethernet)
  • DC IN (barrel connector): to accept coaxial plug 2.1 x5.5 x 9.5 mm, Centre Positive Standard
Operating conditions
  • Temperature range: – 40° C to + 50° C (– 40° F – + 122° F)
Controls and indicators
  • Termination: built-in switchable terminator
  • Termination of CAN-Bus with internal resistor: 120  / 1/4 W / ± 5%, with corresponding status LED
  • Indicators (Status LEDs): ON, CAN, ERROR, LAN, TERMINATE
Connectors
  • LAN (Ethernet): 1 x RJ 45 connector
  • CAN: 2 x RJ 45 connectors, wired in parallel
Hardware
  • Controller: 16 Bit
  • Program Flash: 256 kB
  • Data Flash: 8 MB
  • SRAM Size: 256 kB
  • EEPROM Size: 8 kB
  • Additional features: CAN galvanically isolated
  • CAN Specification: 2.0 A/B
  • CAN-Bus coupling: High Speed, according to ISO 11898, galvanically isolated
  • Max. CAN Baud Rate: 1 Mbit/s
Ethernet Specification
  • Ethernet: 10/100 M Base-F, IEEE 802.3u
  • Power over Ethernet (PoE): IEEE 802.3af
Housing/Dimensions/Weight
  • Housing: Extruded aluminium
  • Dimensions (height x width x depth): 115x110x35 mm [4.5″ x 4.3″ x 1.4″]
  • Weight: 230 g (0.5 lb)

Product Details

RRP
$ 3025.00
Brand
d&b audiotechnik
Product Group
Electonics
Product Category
Networking